锂电池
锂离子电池
电芯规格
Li-ion
Battery
Title
Li-ion Battery Specifications
(Steel)
File No:
QP-09-E167-NH
Version
NO
:B/0
Presentation:
Lithium-Ion
Battery Cell
Specification
Classification:
Sony batteries
Cell Type:
ICR18650NH
June
24, 2008
Technology
Department
Battery Technical Service
Department
Prepared
Checked
Approved
Customer
Approval
(Date)
Control
code
:
0806016
锂电池
锂离子电池
电芯规格
Li-ion
Battery
Title
Li-ion Battery Specifications
(Steel)
Revision
History
Revision
Date
Originator
Description
B/0
2008-6-24
Engineering Center
Original Release
File No:
QP-09-E167-NH
Version NO
:B/0
ICR18650NH
Engineering Center
锂电池
锂离子电池
电芯规格
Li-ion
Battery
Title
Li-ion Battery
Specifications (Steel)
Page
1/11
1.
Scope
This
Specification is applied to rechargeable
lithium ion battery
cell of the
following mentioned type for various
applications in mobile communication
devices and portable power systems.
2.
Cell Classification and
Type
2.1 Cell
Classification
:
Lithium Ion Battery Cell
2.2
Cell Type
:
ICR18650NH
3.
Standard
The
specification is based on the technical
specification of GB/T18287-2000
、
UL1642 and IEC61960.
4.
Nominal
Specification
Item
Specification
Remarks
4.1
4.2
Typical capacity
Minimum Capacity
2600mAh
2500mAh
8.4V
7.4V
8.4
±
0.1V
0.5
C
5
A
0.2
C
5
A
0.2 C
5
A
discharge
4.2 Nominal Voltage
4.3 Discharging Voltage
(Min)
4.4 Charging Voltage
(Max.)
4.5 Charging Current<
/p>
(
Std.
)
4.6 Discharging Current
(
Std.
)
4.7 Charging Current
(Fast
)
4.8
Discharging Current
(
Fast
)
4.9 Discharging Cur
rent
(
Max.
)
1
C
5
A
1
C
5
A
2
C
5
A
0 ~ 40
°
C,
<95%RH
4.10 Internal
Impedance
4.11
Weight
≤
200m
?
100
±
2.0g
4.12
Outline
dimension
(see
figure)
width
φ
38
±
0.2mm
(
Including
PVC
)
Length
Min 1
Month
Min 3
Months
68
±
0.5mm
-20 ~
+60
°
C,
<75%RH*
-20 ~
+45
°
C,
<75%RH*
Initial
status of cell 3.80V and
50% of charge,
the capacity lost
during shipment <
20%.
Capacity
recover rate > 80%.
4.13
Battery
cell
storage
and
transportation
environment
and
temperature
ranges
Min 12
Months
-20 ~
+25
°
C,
<75%RH*
File No:
QP-09-E167-NH
Version NO
:B/0
ICR18650NH
Engineering Center
锂电池
锂离子电池
电芯规格
Li-ion
Battery
Title
Li-ion Battery Specifications
(Steel)
Page
2/11
5.
Electrical Characteristics
Item
5.1 Full
Charge
Test
Method
Performances
The
charger
supplies
1C
constant
current
until
battery
voltage reaches 8.4V
,
then be
changed at constant
voltage of 8.4V
while
tapering the charge current to
less
than or equal to 0.01 C.
Charging time is 3.0 hours in all.
More than 300min
More than
54min
5.2 Capacity
①
Within
1
hour
after
fully
charged,
discharged
at
0.2C
continuously down to 7.4V.
continuously down to 7.4V.
②
Within 1 hour
after fully charged, discharge at 1C
5.3
Cycle life
5.4 Capacity
retention
300 cycles.
(Capacity
testing after 300 cycles will be performed under
condition of
0.5C charging and 0.2C discharging)
After fully charged, stored
for 28 days at 20
°
C, then
for 1
CHINENG
guarantee
that
the
residual
capacity
of
2
cells
in
series
without circuitry is over than 80% after
hour
between
20
°
C
to
25
°
C
and
continuously
discharge
at 1C to
7.4V.
A
battery
unit shall be repeated 300
charge/discharge
cycles,
charged
at
CC-CV
(0.5
C
-
4.2V)
for
3.
0
hours,
discharged
at
0.5C
continuously
down
to
7.4V
Cut-off
≥
80% capacity
Voltage. Measure discharge capacity.
Capacity retention rate
≥
85%
※
Minimun Capacity
The minimum capacity is in the
specifications table. The term refers to the
capacity when the charged cells are
discharged to the cut-off voltage for 5
hours at 20
°
C±
5
p>
°
C.
※
Typical Capacity
Typical capacity refers to the median
value of the capacity when a battery cell is
discharged to the cut-off voltage
with
the current of 0.2 C at 20
°
C
±
5
°
C.
※
Limit Charge
Voltage
Charged cells with
constant current to reach a voltage value, then
keep the voltage constant and continue to charge
them. The voltage is referred to as
limited charge voltage. The value is 4.2V.
※
Cut-off Voltage
Cut-off Voltage Refers to the end
voltage when a battery cell is discharged to
reach. The value is 7.4V.
File No:
QP-09-E167-NH
Version NO
:B/0
ICR18650NH
Engineering Center
锂电池
锂离子电池
电芯规格
Li-ion
Battery
Title
Li-ion Battery Specifications
(Steel)
Page
3/11
6.
Temperature
Adaptability
Item
6.1 Capacity at different temperature
Test Method
Performances
6.2
Discharge at constant
temperature
/humidity
Measure
capacity
with
constant
discharge
current
of
Minimum capacity:
60% at
-20
℃
0.2
C
to
7.4V
cut-off
at
each
temperature
after
80% at 0
℃
complete charge at
20
℃
.
95% at
55
℃
The
battery
cell
shall
not
Percentage as an index of the capacity
compared with
100%
at
20
℃
.Keep
the
battery
at
40
℃
and
90%RH,
rupture,
smoke,
catch
fire,
goal
is
95%,
for
48
hrs
and
then
discharge
at
1C
to
vent
or
leak.
The
time
of
7.4V Cut-
off Voltage.
discharge is no less than
36
min.
The
battery
cell
will
be
vibrated
10
sine sweeps
in
The
battery
cell
shall
not
three
mutually
perpendicular
directions
with
amplitude
rupture,
smoke,
catch
fire,
of
0.19-0.38mm
and
changing
frequency
between
10
vent
or
leak.
The
voltage
is
and
55Hz. The rate of scanning frequency is from
10H
Z
no less than 3.6V.
to 55 H
Z
with the
rate of 1 H
Z
per min.
6.3 Vibration
6.4 Shock
The
battery cell shall be accelerated 1000 times at
100m/s
for durations of 16mS.
2
The
battery
cell
shall
not
rupture,
smoke,
catch
fire,
vent
or leak.
The battery cell will be
dropped free one time in three
The
battery cell shall not
mutually
perpendicular
directions
from
the
height
of
rupture, smoke, catch
fire,
1.0m onto a hard board with the
thickness of 20mm.
vent or
leak.
6.5
Free fall
7.
Safety Characteristics
Item
7.1 Short
Circuit
Test
Method
Performances
The
battery
cell
is
to
be
short-
circuited
by
connecting
The battery cell shall be no
the
positive
and
negative
terminals
of
the
battery
with
fire, somke or
explosion.
an
external
load
of
less
than
100
m
Ω
until
the
surface
temperature
decrease
10
degree
from
the
highest point.
7.2 Over
charge
The
battery
cell
charged
completely
will
be
charged
The battery cell shall be no
continuously for 8hrs with the external
power supply of
fire, smoke or
explosion.
the limit voltage
of 4.6V and the current of 3A.
File No:
QP-09-E167-NH
Version NO
:B/0
ICR18650NH
Engineering Center
锂电池
锂离子电池
电芯规格
Li-ion
Battery
Title
Li-ion Battery Specifications
(Steel)
Page
4/11
7.3 Over discharge
After
complete
charge,
the
battery
cell
will
be
The
battery cell shall not
discharged
to
end
voltage.
Then
connect
with
rupture, smoke, catch fire,
external load of
30
Ω
discharge for 24hrs.
7.4 Crush
vent
or leak.
A charged battery cell is to be crushed
between two
The
battery
cell
shall
not
flat
surfaces.
The
force
for
the
crushing
is
to
be
rupture or catch fire.
7.5
Impact
applied by a
hydraulic ram with a 1.25 inch (32mm)
until
a
pressure
reading
of
17.2Mpa
is
reached
on
the
hydraulic
ram,
applied
force
of
the
maximum
pressure
has
been
obtained
it
is
to
be
released.
diameter
piston.
The
crushing
is
to
be
continued
Drop a 10kg hammer from a height of 1m
onto the
Deformation
of
the
battery
cell
cell
that
is
placed
on
a
flat
surface.
(The
largest
is
allowed,
but
there
shall
be
surface of the battery cell shall be
perpendicular to
no fire or explosion.
the flat surface.)
7.6 Heating
Place
the
battery
cell
in
an
oven.
The
temperature
The battery cell
shall be no fire
of the oven is to be
raised at a rate of 5
℃
±
2
℃
/min
or
explosion.
to a
temperature of 130
℃
±
2
℃
,
and remain for
30min at that temperature.
8
.
Standard Test Conditions
8.1 Test Condition
Unless
otherwise
specified,
all
tests
stated
in
this
Product
Specifications
shall
be
conducted
under
the
following
atmosphere
condition:
Temperature:
15
℃
–
35
℃
;
8.2
Measuring meters & Instruments
8.2.1 Voltmeter should have a precision
of ±
0.5% or higher. Its internal
impedance should not be less than
10k
?/
V.
8.2.2
Ammeter should have a precision of
±
0.5% or higher.
8.2.3 Hour-
meter should have a precision of ±
0.1%
or higher.
8.2.4 Thermometer should
have a precision of
±
0.5
℃
or higher.
8.2.5 The current
of a constant-current supply should be stable and
adjustable.
Its variation shall
be
within ±
1%
during the
charging and discharging
process.
8.2.6 The voltage of a
constant- voltage supply should be stable and
adjustable. Its variation shall be within
±
0.5%.
Relative
Humidity:
45%
–
75%;
Atmospheric Pressure:
86kPa
–
106kPa.
File No:
QP-09-E167-NH
Version NO
:B/0
ICR18650NH
Engineering Center
锂电池
锂离子电池
电芯规格
Li-ion
Battery
Title
9.
Li-ion
Battery Specifications (Steel)
Page
5/11
Design and
Construction
The design,
structure and dimension of the battery cell are
shown on the attached
drawing
(
see
figure
)
.
10.
Appearance
There
shall be no practical damage such as conspicuous
liquid electrolyte leakage, flaw electrolyte
leakage, rust, dirt,
and deformation.
The battery cell must have marketability.
11.
Packing
and Shipping cells
①
Inspection
Before Shipment of the battery cells
?
Inspect
voltage, internal impedance and capacity and
protection circuit function before shipment.
Minimum aging period should be more
than 4 weeks from date of manufacturing.
Outgoing Inspection Report should be
come with Shipment.
②
Packing and Shipping cells
?
During
transportation,
must
use
appropriate
package
to
protect
the
cell
from
damage.
We
recommend
the
original
package method,
whenever need during transportation.
?
The cells
should be shipped
with half-charged
state and during transportation. Avoid mechanical
shock, crush, sun
radiation and shower.
Should be shipped by truck, train, ship or
airplane etc.
Date code on the cells
and box:
- On the cell: Manufacturing
date should be marked on the PVC sleeve, not on
the can.
- On the box: Manufacturing
date and shipping date should be marked.
Manufacturing date should be complied with
cells.
③
Abnormal
cell
?
Don’t use
abnormal cells
which have damages caused by stress, drop, short,
or leakage of electrolyte.
12.
Precautions on Charge use
①
Charge
?
A battery cell
must be charged with constant current-constant
voltage.
?
In
case of ICR18650NH, charge current must be below
2C /cell.
?
Charge voltage must be less than
4.25V/cell.
②
Discharge
?
Discharge
current must be below 2C /cell.
?
Discharge
temperature range should be
-20~55
°
C.
?
Discharge end
voltage must be over 7.4V/cell.
③
Required
protection functions
Have
protection circuit functionality which is
described below inside battery pack, to insure
safety of battery cell in case
of
misuse.
File No:
QP-09-E167-NH
Version NO
:B/0
ICR18650NH
Engineering Center
-
-
-
-
-
-
-
-
-