关键词不能为空

当前您在: 主页 > 英语 >

IICL国际验箱师新版题

作者:高考题库网
来源:https://www.bjmy2z.cn/gaokao
2021-02-13 19:26
tags:

-

2021年2月13日发(作者:受让)




CL




TEST




2


1.



What is purpose of Guide for Container Equipment inspection?


a. to reveal ctrs conditions





b. to set a serial criteria for ctr inspection



c. to determine how to repair the ctr





d. to determine the measurement method



2.



According to the Guide for inspection, when does the inspector inspect the ctr?


a. on-hire/off-hire interchange






b. after a major repair


c. before refurbishment











d. transfer from one mode of transport to another


3.



What should be recorded in the EIR?


a.



all the damage, wear and non-conforming repair



b.



all the damage, wear and non-conforming repair for which repair are needed


c.



all the damage, wear for which repair are needed


d.



only damage


4.



For identification purpose, the transverse member are numbered?


a.



beginning at door end, including the door sill


b.



beginning at door end, not including the door sill


c.



beginning at front end, including the door sill


d.



beginning at front end, including the front sill









tunnel is positioned at:


a.
















b. the door end





c .the right end



d. the left end


crossmembers between tunnel rails are called:


a.












b. tunnel stiffener






c. tunnel boslter




d .tunnel plate


ng to the Guide for inspection. Which one is correction open-top ctr:


a.



the header pin is secured to the header by a header pin chain


b.



the header pin is secured to the top said rails by a header pin chain


c.



the header pin is secured to the corner







by a header pin chain


c.



none of them


floor is need to support longtudinally in the center of the ctr?


a. solid or laminated hardwood planks



b. solid or laminated softwood planks


c. plywood panels







d. a combination afternating wooden and steel planks








plate extends from the door door sill to:


a. the second crossmember





b. the front crossmember


c. the third crossmember






criteria


idated date plate include:



. CSC plate.




.


ISO marking plate



.


TCT.

< p>



customs



owner marking plate.


a.



-








b.



-






c.



-






d.


①③④



does non-conforming repair mean?


a.



not being performed in accordance with



CL recommend repair methods


b.



not


being


performed


in


accordance


with



the


applicable


government


recommend


repair


methods


c.



not being performed in accordance with



the local recommend repair methods


d.



none of them


ing to the Guide for inspection, what kinds of non-conforming repairs requiring repair


should contact the ctr owner?


a.



the damage still exceeds



CL inspection criteria limits



1



b.



the damage unacceptable, but not exceeds



CL inspection criteria limits


c.



the damage acceptable








d. all of them


header and flat-bar top side rail bend etc. Except on a header extension plate or corner


protection plate, deep









required repair?


a.15mm






b.35mm






c.25mm






d.30mm


-section top side rail distort deep








not required repair?


a.40mm






b.35mm






c.30mm






d.31mm


corrugated roof panels bend etc. The criteria of repair is











.


a. more than 30mm










b. more than 35mm


c. more than 50mm









d. more than 25mm


any deformation on corner protection plate and header extension plate. Which one dosen



t


need repair?


a.



upwards 3.5mm above plane of upper surface of top corner fittings


b.



the internal dimension are reduce 40mm


c.



both all right






d. none of them


ing to the Guide, when the ctr interior has the following defects. Which one doesn



t


need repair ?


a. organic cargo residues










b. graffiti


c. tire marks




















d. persistent odor


the ctr exterior has hazardous cargo labels, which action is correct?


a. repair







b. not repair





c. report to the owner





d. none of them


ing to the



CL+ISO damage limits, the length of gooseneck tunnel is



.3140mm. max.3510mm








b. min.3130mm. max.3500mm


c. min.3150mm. max.3520mm







d. min.3120mm. max.3500mm


ing to the



CL+ISO damage limits, the front sill of 40ft, ctr outwards as following,


which statement is correct?


a.



Max. 5mm beyond plane of end surface of corner fittings


b.



Sill face must be at least 4mm behind plane of corner fittings


c.



Sill face must be at least 2mm behind plane of corner fittings


d.



Sill face must be at least 1mm behind plane of corner fittings


outwards dent on corner post, which one need repair?


a.



15mm deep, not exceed has surface of the corner fittings


b.



10mm deep, not exceed has surface of the corner fittings


c.



20mm deep, not exceed has surface of the corner fittings


d.



25mm deep, not exceed has surface of the corner fittings


a dent on the tunnel stiffeners, deep is









requiring repair


a. more than 35mm












b. more than 50mm


c. more than 30mm












d. more than 40mm


impact causes a 10mm deep dent in the top-side rail, at the same time, the adjacent side


panel dents inwards by 40mm depth, what is the correct action?


a.



both the top side rail and side panel must be repaired


b.



only the side panel must be repaired


c.



only the top- side rail must be repaired






d. none of them


we set a reference line?



2



a.



to establish the original, undamaged profile of the damage area


b.



to decide the damage which need repair and which don



t need repair


c.



to measure the damage depth







d. none of them


convex damage, the correct calculation method is :


a. D=M-S







b. D=S-M







c. M=D-S








d. S=M-D


26-30 for open-top CTRS


is a dent on drip pans, deep






need repair?


a.52mm









b.30mm








c.38mm










d.35mm


criteria of different height of surface of adjacent planks is more than







need repair.


a.5mm










b.8mm









c.10mm










d.15mm


pins bend to extent that they don



t fit over entire length of pin, it needs:


a. repair









b. Not repair





c. can



t decide






d. None of them


is a dent on roof




, which downwards 51mm, the correct action is:


a. repair









b. Not



repair






c. can



t decide






d. Report to the owner


seals cracks, but it still water right, the correct action is


a. repair









b. let in alone







c. can



t decide






d. Report to the owner



in


an


upwards


bent


on


the


interior


surface


of


the


roof


sheet


in


the


flat


area


between


corrugation, the reference line should be placed:


a.



the undamaged area


b.



horizontally across the roof sheets width in the interior side


c.



put the same thickness spacers on the undamaged area, then set the reference line


d.



put the same thickness spacers on the top-side rail , then horizontally set the reference


line


ing


to



CL



s


criteria,


the


end


frame


may


not


exceed







beyond


the


vertical


surface of the corner fittings?


a. more than 5mm






b. more than 10mm





c. more than 15mm




d. more than 4mm



put


spaces


on


the


corner


fittings,


the


thickness


of


spaces


is


8mm,


the


measure


result


as


following, which need repair? (end frame)


a. 1mm








b. 2mm







c. 3mm







d.4mm


is a localized damage to an end rail, the reference line should be placed:


a. over the undamaged area





b. over the full length of the rail


c. both of right















d. none of them


ing damage to headers with corner protection plate, the best way is:


a.



the reference line may be placed on the corner fittings


b.



the reference line may be placed on the top surface of the corner fittings


c.



the reference line may be placed on the undamaged portion


d.



none of them


door sills has cut-outs, the reference line should be placed:


a.



on the outer surface of the corner fittings


b.



cross the full length of the door sills


c.



both of right
















d. none of them


measuring damage to side and front panel, the reference line must be placed:


a. over the height of the panel










b. vertically



c. only on the either ends of the undamaged area





d. none of them



3

-


-


-


-


-


-


-


-



本文更新与2021-02-13 19:26,由作者提供,不代表本网站立场,转载请注明出处:https://www.bjmy2z.cn/gaokao/652262.html

IICL国际验箱师新版题的相关文章