OTIS
CHINA
Part:
Field
Instruction
No.:
AT120
Adjusting
Manual
Page:
1/9
Date
:
2004,9
AT120
DOOR
ADJUSTING
MANUUAL
START UP
Before switch on
the power
Written by
Wang zhe
Checked
by
Approved by
OTIS
CHINA
Part:
Field
Instruction
No.:
AT120
Adjusting
Manual
Page:
2/9
Date
:
2004,9
Check the connections on the control
board :
- Motor and encoder connected
on ST306.
- I/O and 24 VDCon P5.
- Power supply from the transformer to
he connector ST1.
- Power supply from
the transformer into the junction box on the
connector.
Atfer mecanically
adjusting the car door with the landing doors (gap
of locking +
couplingdimension)
,
the electrical adjustment
can start.
- Put the car on INSPECTION
mode in front of one of landing door
-
From the top of car , open handly the door and
position it in opened position.
-
Switch on the power on the operator (wait 30/ 40
seconds for the
box)
- Push
the learning and adjustment button at least 3
seconds.
The door is on LEARNING mode
and does 1 or 2 opening and closing cycles
- Connect the Service Tool on the SVT
connector to open and close the
door
.
Welcome to ATAX
Atxx = 3
Press
Press
Monitor =
1 Test = 2
Tools =
4
Single Run = 1
Press
Cont Run = 2
Press
Open = 1 Close = 2
Stop = 3 Revels =
4
Press on
Written by
Wang zhe
Checked
by
- If it does not
work properly, connect the test tool on the SVT.
Approved by
OTIS
CHINA
Part:
Field
Instruction
No.:
AT120
Adjusting
Manual
Page:
3/9
Date
:
2004,9
- Switch
off the power
SELF TEST
OK-
MECS-MODE
Press
“Module
”
Press “3”
Press “SHIFT 7
”
Press “3”
Written by
Wang zhe
power
on
SELF TEST IN
PROGRESS
SELF TEST
OK-
MP2/3-MODE
Welcome to Atxx
Atxx =
3
Monitor = 1
Test = 2
Tools = 4
Monitor = 1 Test = 2
Setup = 3 Tools = 4
Install = 1
Field = 3 ENG = 4
Install = 1
Field = 3 ENG = 4
Checked by
Approved by
OTIS
CHINA
Part:
Field
Instruction
No.:
AT120
Adjusting
Manual
Page:
4/9
Date
:
2004,9
Press “3”
Press “1”
Config = 1
SetDef = 9
Start learn run
Press “ENTER”
Open car doors
manually on the top
Press “ENTER”
Start “ENTER”
Press “1”
Init Run = 1
Door Para Run =
2
Door is running
Stop Door run = 3
The door open and close
10cm
Written by
Wang zhe
Checked by
with low speed
rpeatedly, then
Approved by
close with low speed
-
-
-
-
-
-
-
-
-
上一篇:HDIV使用手册