故障实例:
1
、
RAID5
一块硬盘掉线
2950
在
0
,
1
,
2
三个硬盘槽位分别接入了
ST
1TB SATA
硬盘,配置成
RAID 5
。
开机后发现有一块硬盘指示灯不亮,显示器上并提示如下:
some configured disks have
been removed from your system or are no longer
accessible.
please check you cables and also ensure
all disk are any key to
continue,or
'C' to load the
configuration utility.
按
键盘
上的
C
键后,出现提示如下:
Entering the configuration
uility in this state will result in drive
configuration
changes .press 'Y' to
continue loading the configuration utility or
power off your
system and check your
cables to ensure all disk are present and reboot
按
键盘
上的
Y
键后
进入
R
AID
配置界面,没有看到在
1
号位的
硬盘,提示:
MISSING
,
RAID 5
状
态为
Degraded
然后重启机器后,
发现
原来指示灯不亮的硬盘,
指示灯开始
变为橙色,后又
变成绿色
提示:
Fw
package:6.0.2
—
0002
2
virtual
Driver(s) found on the host adapter
1
virtual Driver(s) Degraded 2 virtual Driver(s)
handled by BIOS
foreign
configuration(s) found on adapter
press any key to continue
or 'C' load the configuration utility or 'F' to
import foreign
configuration (s) and
continue
然后,
在
RAID
配置界面里将掉线的,
导入。
后恢复正常后,
不久该硬盘又掉线,
怀疑硬盘
有问题。
导入的时间将近
4
个小时,<
/p>
数据量
2G
多,
硬盘上就光一个
RHEL5
定制的系统
RAID 5
更换
1
块坏硬盘。
0
,
1
,
2
三块插槽位配置
RAID5
。
1
插槽位的驱动器
状态由绿变橙。预报警。现
更换
1
处的硬盘。