实用标准文案
LTE R12 UE
category
和
category
DL/UL
区别规范
1
、
ue-Category
The
field
ue-Category
defines a
combined uplink and downlink capability. The
parameters set by the UE Category are
defined in subclause 4.2. Tables 4.1-1 and 4.1-2
define the downlink and, respectively,
uplink physical layer parameter values for each
UE Category. A UE indicating category 6
or 7 shall also indicate category 4. A UE
indicating category 8 shall also
indicate category 5. A UE indicating category 9
shall also
indicate category 6 and 4. A
UE indicating category 10 shall also indicate
category 7 and
4. A UE indicating
category 11 shall also indicate category 9, 6 and
4. A UE indicating
category 12 shall
also indicate category 10, 7 and 4. Table 4.1-4
defines the minimum
capability for the
maximum number of bits of a MCH transport block
received within a
TTI for an MBMS
capable UE.
Table 4.1-1: Downlink
physical layer parameter values set by the field
ue-Category
文档
实用标准文案
UE
Category
Maximum number
of
DL-SCH
transport block
bits
received
within a TTI (Note
1)
Category 1
Category 2
Category 3
Category 4
Category 5
Category 6
10296
51024
102048
150752
299552
301504
Maximum
number of bits
of a DL-SCH
transport block
received
within
a TTI
10296
51024
75376
75376
149776
149776 (4 layers,
64QAM)
75376 (2 layers,
64QAM)
Category 7
301504
149776 (4 layers,
64QAM)
75376 (2 layers,
64QAM)
Category 8
Category 9
2998560
452256
299856
149776 (4 layers,
64QAM)
75376 (2 layers,
64QAM)
Category 10
452256
149776 (4 layers,
64QAM)
75376 (2 layers,
64QAM)
Category 11
603008
149776 (4 layers,
64QAM)
195816 (4 layers,
256QAM)
75376 (2 layers,
64QAM)
97896 (2 layers,
256QAM)
Category 12
603008
149776 (4 layers,
64QAM)
195816 (4 layers,
256QAM)
75376 (2 layers,
64QAM)
97896 (2 layers,
256QAM)
文档
7308288
2 or 4
7308288
2
or 4
5481216
2 or 4
35982720
5481216
8
2 or 4
3654144
2 or 4
250368
1237248
1237248
1827072
3667200
3654144
1
2
2
2
4
2 or 4
Total number
of soft channel
bits
Maximum
number of
supported layers
for spatial
multiplexing in
DL
实用标准文案
NOTE 1:
In carrier aggregation operation, the
DL-SCH processing capability can be shared by
the UE with that of MCH received from a
serving cell. If the total eNB scheduling for
DL-SCH and an MCH in one serving cell
at a given TTI is larger than the defined
processing capability, the
prioritization between DL-SCH and MCH is left up
to UE
implementation.
Table 4.1-2: Uplink physical layer
parameter values set by the field
ue-
Category
UE Category
Maximum
number of
UL-SCH transport
block bits
transmitted
within a
TTI
Category 1
Category 2
Category 3
Category 4
Category 5
Category 6
Category 7
Category 8
Category 9
Category 10
Category 11
Category 12
5160
25456
51024
51024
75376
51024
102048
1497760
51024
102048
51024
102048
Maximum
number of bits of
an UL-SCH
transport block
transmitted
within a TTI
5160
25456
51024
51024
75376
51024
51024
149776
51024
51024
51024
51024
No
No
No
No
Yes
No
No
Yes
No
No
No
No
Support for
64QAM in UL
Table 4.1-3: Total layer 2 buffer sizes
set by the field
ue-Category
文档
实用标准文案
UE
Category
Category 1
Category
2
Category 3
Category 4
Category 5
Category 6
Category 7
Category 8
Category 9
Category 10
Category 11
Category 12
Total layer 2 buffer
size
[bytes]
150 000
700 000
1 400 000
1 900 000
3 500 000
3 300 000
3 800 000
42 200 000
4 800 000
5 200 000
6 200 000
6 700 000
With support for
split
bearers
230 000
1 100 000
2 300 000
3 100 000
5 900 000
5 800 000
6 200 000
61 600 000
7 200 000
7 600 000
11 000 000
11 500 000
Table 4.1-4: Maximum number
of bits of a MCH transport block received within a
TTI set by the field
ue-
Category
for an MBMS capable UE
UE Category
Maximum
number of bits of
a MCH transport
block
received
within a TTI
Category 1
Category 2
Category 3
Category 4
Category 5
Category 6
Category 7
Category 8
Category 9
Category 10
Category 11
Category 12
10296
51024
75376
75376
75376
75376
75376
75376
75376
75376
75376 (64QAM)
97896 (256QAM)
75376 (64QAM)
97896 (256QAM)
文档
实用标准文案
Table
4.1-5: Half-duplex FDD operation type set by the
field
ue-Category
for a
half-duplex FDD capable UE
UE Category
Category 1
Category 2
Category 3
Category 4
Category 5
Category 6
Category 7
Category 8
Category 9
Category 10
Category 11
Category 12
Half-duplex FDD
operation type
Type A
Type A
Type A
Type A
Type A
Type A
Type A
Type A
Type A
Type A
Type A
Type A
2
ue-CategoryDL and ue-CategoryUL
The fields
ue-
CategoryDL
and
ue-
CategoryUL
define downlink/uplink
capability
respectively. The parameters
set by the UE DL/UL Categories are defined in
subclause
4.2. Tables 4.1A-1 and 4.1A-2
define the downlink and, respectively, uplink
physical
layer parameter values for
each UE DL/UL Category
Table
4.1A-4 defines the minimum
capability
for the maximum number of bits of a MCH transport
block received within a
TTI for an MBMS
capable UE. Table 4.1A-6 defines the only
combinations for UE UL and
DL
Categories that are allowed to be signalled with
ue-CategoryDL
and
ue-CategoryUL
.
Table 4.1A-6 also defines which UE
Categories a UE shall indicate in addition to the
combinations for UE UL and DL
Categories.
文档
实用标准文案
Table
4.1A-1: Downlink physical layer parameter values
set by the field
ue-
CategoryDL
文档
-
-
-
-
-
-
-
-
-