Ixia Software Release Notes
IxNetwork 5.30 EA SP5 Patch1
Build Number: 5.30.90.120
(June 22, 2009)
About This
Release
Licensing
Installation Notes
Tcl/Tk Support for Client
Applications
How to Report
Problems
Additional
Documentation
What's New in
IxNetwork
About
This Release
IxNetwork 5.30
EA SP5 Patch1 is an
support for
IxNetwork-FT (Feature Test) replacing support for
the legacy IxRouter
application.
See the specific IxNetwork-
FT sections below for application compatibility
requirements and known
issues. See the Product Compatibility Matrix for
IxNetwork-FT hardware
support.
Upgrading from a
release prior to IXOS 5.10 SP2
To ensure proper operation of an Ixia
chassis with IxOS 5.10 EA SP3, prior to
installing this release you
must un-install all previous versions of Ixia
applications,
Ixia StatEngine, Ixia
StatEngine PCPU packages and IxOS. You should use
the Add/Remove
utility in
the Windows Control Panel.
After the uninstallations are complete the
chassis must be rebooted.
IxOS Compatibility
IxNetwork 5.30
EA SP5 Patch 1 requires minimum IxOS 5.20 GA Patch
2 or IxOS 5.30
EA SP2 Patch1 or later
versions of IxOS 5.30 to be installed.
Previous Release Notes
Please visit the IxNetwork
support web page for more information on previous
Release Notes.
Application
Compatibility
NOTE: When
you are using one or more of the applications
below on a single
chassis
configuration, please use the correct application
versions so they align
to a common
version of IxOS.
Application
IxOS 5.20 GA Patch2
IxOS
5.30 EA SP2 Patch1
IxNetwork
5.30 EA SP5 Patch1
5.30 EA
SP5 Patch1
IxNetwork-FT 5.30 EA SP5
Patch1
5.30 EA SP5 Patch1
HLTAPI
3.40 GA
3.40 GA
IxAccess 2.40 GA
Patch2
N/A
IxAdmin
1.00 GA SP2
1.00 GA SP2
IxANVL
7.55 EA
7.55 EA
IxAuthenticate
2
.0 GA SP2 Patch2 N/A
IxAutomate
6.60 GA
6.60 GA
IxChariot 6.70 EA
N/A
IxDefend 3.20 EA
3.20 EA
IxLoad-VoIP
N/A 3.70 EA
IxLoad
4.10 EA SP1 Patch1
4.20 EA
(*)
IxSAN
N/A 1.00 EA SP1
IxVPN
3.00 GA SP3 Patch3
3.00 GA SP3 Patch3
Licensing
2
.50 GA Patch3
2.70 EA SP1
Stack Manager
3.35 EA
3.35 EA
Test Conductor
2.10 EA
2.10 EA
VNIC
2.50
EA
2.50 EA
For
the latest compatibility information to include
releases occurring after this
date,
please refer to the online Product Compatibility
Matrix at the link below.
An Ixia
website account is required before accessing.
/support/product_compatibility_matrix
IxNetwork Load Module Support
NOTE: Not all hardware
listed below is currently supported by IxNetwork-
FT.
See the online Product
Compatibility Matrix for IxNetwork-FT specific
Load Module
support.
Module
Type
Supported Function
M
odule Part Number
10G Ethernet
Control Plane
Testing
LSM10G1-01, LSM10GXL6-01 (LAN),
LSM10GXL6-02
(LAN/W
AN),
LSM10GXM3-01,
LSM10GXMR3-01,
LM10GE700F1-P,
LM10GE700F1B-P,
LM10GULF-P,
LM10GUPF-XFP, LSM10GXM2XP-01, LSM10GXM4-01,
LSM10GXM4XP-01,
LSM10GXMR2-01,
LSM10GXMR4-01,
LSM10GXM8-01,
LSM10GXM8XP-01,
LSM10GXMR8-01,
LSM10GR1-01,
10GBaseT-ADAP-01,
LSM10GXM2S-01,
LSM10GXM4S-01,
LSM10GXM8S-01,
LSM10GXMR2S-01,
LSM10GXMR4S-01,
LSM10GXMR8S-01
Stateless
Data Plane Test
L
SM10G1-01,
LSM10GXL6-01 (LAN), LSM10GXL6-02
(LAN/W
AN),
LSM10GXM3-01,
LSM10GXMR3-01, LSM10GL1-01, LSM10GXM2XP-01,
LSM10GXM4-01,
LSM10GXM4XP-01,
LSM10GXMR2-01,
LSM10GXMR4-01,
LSM10GXM8-01,
LSM10GXM8XP-01,
LSM10GXMR8-01,
LSM10GR1-01,
10GBaseT-ADAP-01,
LSM10GXM2S-01,
LSM10GXM4S-01,
LSM10GXM8S-01,
LSM10GXMR2S-01,
LSM10GXMR4S-01, LSM10GXMR8S-01
Application Traffic LM10GE700F1-P,
LM10GE700F1B-P,
LSM10G1-01,
LM10GXM3-01,
10GBaseT-
ADAP-01,
LSM10GXM2XP-01,
LSM10GXM4-01,
LSM10GXM4XP-01,
LSM10GXM8-01,
LSM10GXM8XP-01,
LSM10GR1-01,
LSM10GXM2S-01,
LSM10GXM4S-01, LSM10GXM8S-01
10/100/1G Ethernet
C
ontrol Plane Testing
ASM1000XMV12X-01,
LM1000STXS2,
LM1000STXS4,
LM1000STXS4-256,
LM1000TXS4,
LM1000STXR4,
OLM1000STXS24,
LM1000SFPS4,
ALM1000T8,
ELM1000ST2,
CPM1000T8,
LSM1000XMS12-01,
LSM1000XMSR12-01,
LSM1000XMV4-01,
LSM1000XMVR4-01,
LSM1000XMV8-01,
LSM1000XMVR8-01,
LSM1000XMV12-01,
LSM1000XMVR12-01,
LSM1000XMV16-01,
LSM1000XMVR16-01,
ACCELERON-
NP-01
(Non-Aggregate
Mode),
ACCELERON-XP-01
(Non-
Aggregate Mode)
Stateless Data Plane
Test
A
SM1000XMV12X-01,
LM1000STXS4,
LM1000STXS4-256,
LM1000TXS4,
LM1000STXR4,
OLM1000STXS24,
LM1000SFPS4,
LSM1000XMS12-01,
LSM1000XMSR12-01,
LSM1000XMV4-01,
LSM1000XMVR4-01,
LSM1000XMV8-01,
LSM1000XMVR8-01,
LSM1000XMV12-01,
LSM1000XMVR12-01,
LSM1000XMV16-01,
LSM1000XMVR16-01,
ACCELERON-
NP-01
(Non-Aggregate
Mode),
ACCELERON-XP-01
(Non-
Aggregate Mode)
Application Traffic
ASM1000XMV12X-01,
LM1000STXS4,
LM1000STXS4-256,
LM1000TXS4,
LM1000SFPS4,
ALM1000T8,
CPM1000T8,
LSM1000XMS12-01,
LSM1000XMV4-01, LSM1000XMV8-01,
LSM1000XMV12-01, LSM1000XMV16-01
OC192
SONET
Control / Stateless Data Plane
Testing
MSM10G1-01, MSM10G1-02
OC48 SONET Control / Stateless Data
Plane Testing
MSM2.5G1-01
OC3/12 SONET/A
TM
Control / Stateless Data Plane Testing
LM622MR, LSM622MR-512
Load
modules
with
32MB
or
less
of
memory
are
not
supported
by
IxNetwork
5.30
EA
SP5
Patch1.
There are several models of Ixia OC-192
and 10G Ethernet modules in this
category. Memory upgrades are
available:
- TRI-045: LMOC192c 128MB
Memory Upgrade
- TRI-046: LM10GE 128 MB
Memory Upgrade
Please contact Ixia for details.
Licensing
IxNetwork 5.30 EA SP5 Patch1 requires
that a license for its use be installed for each
chassis used by IxNetwork.
That license may be installed on each chassis or
on a
server on your
network, referred to as the central license
server.
NOTE: IxOS 5.00 SP2
and later versions of IxOS also require a license.
Please
read the IxOS release notes for license
operation and installation
instructions.
IxNetwork 5.30 EA SP5 Patch1 ships with
Ixia Licensing 2.70 EA SP1.
Installing a License
If you wish to use a central license
server, make sure to install the Licensing
Package on that server.
This can be downloaded from the Ixia Support
website.
If you are
upgrading from an earlier version of IxNetwork or
IxRouter or are
evaluating
IxNetwork, please jump ahead to
If this is a new installation of
IxNetwork, you should have received an email
with your Registration
Number and Password. If you have not received it
yet,
please jump ahead to
Your license is installed
using the Ixia Registration Utility (IRU) from the
start menu
(Start->Ixia->Licensing->IRU). You may run the IRU
from the chassis
or from
any Windows host connected to the chassis. Select
the Register choice
and
press the Start button. Follow the instructions on
the screen. In Step 2,
enter the name or IP address of the
chassis that the license will apply to. In
step 3, if you are using a
central license server, select 'No' and enter the
name
of the license server.
If you are not using a central license server,
select
'Yes' instead.
Using a License Server
If you will be using a
central license server with IxNetwork, make sure
to set
the name of the
server in IxNetwork's Settings->Preferences menu
choice.
To allow use of a
central license server by the Tcl API, a new
system environment
variable
your Tcl program on a UNIX
client, the environment variable must be set on
the
host running the Tcl
Server. Environment variables are set on a UNIX
host through
the user's
shell initialization script. Environment variables
are set on a Windows
host
by using the following instructions:
1. Right-click on the My Computer icon
on the desktop and then left-click on
Properties.
2. Choose the
Advanced tab from the System Properties dialog
box.
3. Press the Environment Variable
button at the bottom of the page.
4. In
either the
if IXN_LICENSE_SERVER does
not exist in the list, press New, otherwise press
Edit.
5. The name of the
variable should be IXN_LICENSE_SERVER and the
value should be
the name or IP
address of the license server machine.
Updating Licenses
Ixia has made changes to its licensing
technology to minimize license update
requirements. In the past license
updates were required with every software
upgrade. Moving forward
license updates will be required at most once
every year
when software
maintenance is renewed.
In
order to move to this new licensing paradigm,
current users of IxNetwork will
need to update their existing licenses
once. For some customers (if you bought
or renewed maintenance for
IxNetwork in the first couple of months of 2007)
this
process will not be
necessary.
The
process to update a license is as follows:
1. Run the Ixia Registration Utility
(IRU) from the start menu (Start->Ixia->
Licensing->IRU).
2. You may run the IRU from the chassis
or from any Windows host connected to
the chassis.
3.
Select the Update option and follow the
instructions on the screen to
complete this
process.
Using
a Temporary License
It is
possible to use IxNetwork for a period of time
prior to installation of a
permanent license through the use of a
temporary license. When you first connect
IxNetwork to a chassis, if
there is no license found for the chassis, you
will
be offered the
opportunity to install a temporary license. A
permanent license
should be
installed before the expiration of the temporary
license. You will
receive
warnings from IxNetwork prior to the expiration of
the temporary license.
Installing Licensing Software
The Ixia licensing package
is installed as part of the IxNetwork server
component
installation. In
some cases you will receive the following message:
to make a change to your
system. If you are connected to the Internet, all
of
-
-
-
-
-
-
-
-
-
上一篇:Synopsys安装和license制作简易教程